Multiparameter water level probe MPS-PTEC

  • Multi-parameter sensor for detecting pressure, temperature and conductivity
  • High-quality 4-electrode conductivity measuring cell
  • Ceramic-capacitive pressure sensor with high measuring accuracy (0.05% FS) and long-term stability (0.1%/year)
  • Robust, sleek Ø 22 mm grade 1.4539 stainless-steel housing for extreme conditions
  • Output: RS485, Option: MOD-BUS, SDI-12, 4-20 mA
  • Optional with integrated data logger: variant “Dipper-PTEC
Categories ,

Share This Items :

Wide measurement range, high resolution:
The MPS-PTEC comes equipped with anautomatic meaasuring range switch (0-0.2 mS/cm; 0.2-2 mS/cm; 2-20 mS/cm; 20-200 mS/cm) which ensures that the best resolution is always available even with significant measuring range fluctuations.

Plug-and-play:
Convenient connection with a SEBA data logger via RS485 or process control systems (MODBUS, 0/4-20 mA), easy configuration and calibration via RS232-USB interface cable using operating software ConfigPC (Windows).

Last but not least:
In addition to conductivity measurement;  salinity, TDS values and water density can also be calculated and displayed.

  • Monitoring of conductivity, water level and water temperature in surface water: rivers, canals, springs, lakes
  • Groundwater: extraction wells, field measurement sites, landfill and construction sites
  • Other applications include: discharge monitoring, swelling pressure measurement
Data collector:

External:

Internal:

Calibration:

Dual converter (USB/RS232 – RS485)

Operating software:

SEBAConfig (Windows)

Parameters:

Water level [cm], [m]

Sensor:

Relative pressure sensor

Measurement principle:

Capacitive with ceramic measuring cell

Measuring range:

0-2/5/10/20/30/40/50/70/100/200m water column or according to specifications

Measuring accuracy:

± 0.05% FS

Long-term stability:

± 0.1% / year

 

Parameters:

Water temperature [°C]

Sensor:

NTC30 with polynomial linearisation

Measurement principle:

NTC resistance

Measuring range:

-5 – +50°C

Measuring accuracy:

0.1°C

Pressure Range:

0-20 bar

 

Parameters:

Conductivity [µS/cm], [mS/cm]

Derived parameters: solutes [g/l], salinity, density [g/l]

Sensor:

4-electrode measuring cell

Measuring range:

0-200mS/cm (total)

Automatic measuring range switchover: 0-200µS/cm; 0,2-2mS/cm; 2-20mS/cm; 20-200mS/cm

Measuring accuracy:

± 1µS/cm for measuring range of 0-200µS/cm +/- 0,5% for measuring range of 0,2-200mS

Pressure Range:

0-30 bar

 

Housing
Material:

Grade1.4539 stainless steel

Dimensions:

Ø22mm, length: 320mm

Protection class

Probe: IP68

RS485 interface: IP67 (immersion depth with a desiccant cartridge up to 3 m, depending on the cable length)

 

Outputs:

RS485 (SHWP) standard, MODBUS, SDI12, 4-20mA (Option)

 

Communications
Interface:

RS232

 

Power supply:

4-15 VDC

 

Operating temperature:

-5°C – +60°C (non-freezing)

 

Hanging depth:

up to 1000m

 

Cable:

Reinforced special measuring cable with pressure compensation line